![]() The simulation results were in good agreement with the maxima of 19% and 7% compared to analytical calculations at different indoor air velocities in the open- and closed-door scenarios, respectively. Moreover, the highest concentrations of radon were measured close to the floor and the lowest values were recorded near to the inlet, resulting in the airflow velocity profile. The average radon concentration from the CFD simulation was found to be between 70.21 and 66.25 Bq m −3 under closed and open-door conditions, respectively, at the desired ventilation rate of 1 ACH (Air Changes per Hour). The CFD code ANSYS Fluent 2020 R1 based on the finite volume method was employed before the simulation results were compared with analytical calculations as well as passive and active measurements. In this paper, the indoor radon distribution in a typical naturally ventilated room under two scenarios (when the door is closed and open) using the computational fluid dynamics (CFD) technique was studied. ![]() However, proper ventilation and sustainability are the major factors that influence how healthy the environment in a building is for its occupants. Therefore, the indoor radon concentration should be monitored and control in dwelling and workplaces. Based on the European Union Basic Safety Standards to protect people against exposure to ionizing radiation, establishing and addressing the reference levels for indoor radon concentrations is necessary. ![]()